AB Allen-Bradley MicroLogix 1762-OB16 - Modulo 16DO

R$2.688,00
Entregas para o CEP:
Meios de envio

Módulo Micrologix 16DO 1762-OB16

Consulte-nos sobre a sua necessidade!

MicroLogix Expansion I/O

Our Bulletin 1762 MicroLogix™ Expansion I/O modules extend the capabilities of the MicroLogix 1100, 1200, and 1400 controllers by maximizing flexibility of the I/O count and type. The modular, rackless design enhances cost savings and reduces replacement parts inventory. Modules can be either DIN rail or panel mounted.

Catalog Number 1762-DO16
Description 1762 MicroLogix 1400 System, 16 Point 24 VDC Sink/Source Input Module
Outputs 16 (8 points/group)
Voltage Category 24V DC sink/source
Operating Voltage Range 10…26.4V DC
  10…30V DC⋆ ‡ 
  ‡ Only applicable for series B.
  ⋆ See MicroLogix 1762-IQ16 DC Input Module Installation Instructions, publication 1762-IN010, for derating chart.
Output Current 10mA 
Impedance, Nom. 3 kW
Signal Delay, Max. On/Off: 8 ms
Off-State Voltage and Current, Max. 5V DC
  1.5 mA
Bus Current Draw, Max. 70 mA at 5V DC (0.35 W)‡ 
  1762 MicroLogix Expansion I/O Modules
Operating Temperature -20…65 °C (-4…149 °F) (on selected modules)
Operating Humidity 5…95% noncondensing
Operating Altitude, Max. 2,000 m (6,561 ft)
Vibration, Operating 10…500 Hz, 5 g, 0.015 in peak-to-peak
Vibration, Relay Operation 2 g
Shock, Operating 30 g panel mounted, 20 g DIN-rail mounted
Shock, Relay Operation 7.5 g panel mounted, 5 g DIN rail mounted
Shock, Nonoperating 40 g panel mounted, 30 g DIN rail mounted
Dimensions (HxWxD), Approx. 90 x 40 x 87mm (3.543 x 1.575 x 3.425 in.)⋆ 
Radiated and Conducted Emissions EN50081-2 Class A
ESD Immunity (IEC 1000-4-2) 4 kV contact, 8 kV air, 4 kV indirect
Radiated RF Immunity (IEC 1000-4-3) 10V/m, 80…1000 MHz, 80% amplitude modulation, +900 MHz keyed carrier
EFT/B Immunity (IEC 1000-4-4) 2 kV, 5 kHz
Surge Transient Immunity (IEC 1000-4-5) 2 kV common mode, 1 kV differential mode
Conducted RF Immunity (IEC 1000-4-6) 10V, 0.15…80 MHz‡ 
  ⋆ Height including mounting tabs is 110 mm (4.33 in.).
  ‡ Conducted immunity frequency range may be 150 kHz…30 MHz if the radiated immunity frequency range is 30 MHz…1000 MHz